Basic operation – Rockwell Automation 700-HX Multifunction Digital Timer User Manual

Page 26

Advertising
background image

Publication 700-UM002B-EN-D - June 2010

Functions 3-15

Z mode: ON/OFF-duty Adjustable Repeat Cycle

S mode: Stop Watch (Timer Resets when Power Comes On)

Power

Start signal

Gate

Reset

Control output

ON duty setting
(%) ON time

0

0

DOWN

UP

ON duty setting
(%) ON time

Cycle time

Cycle time

Timing
diagram

Timing starts when the start signal goes ON.
The status of the control output is reversed
when time is up (ON at start).
While the start signal is ON, the timer starts when
power comes ON or when the reset input goes OFF.

Basic Operation

Power

**

Start signal

input

Output

* Normal output operation will not be possible if the

set time is too short.
Set the value to at least 100 ms (contact output
type).

** Start signal input is enabled during timing.

Timing
ON duty (%)

Timing
(cycle time)

Timing
(cycle time)

Timing
ON duty (%)

9999

Set time

0

Set time

0

UP

DOWN

Power

Start signal

Gate/Reset

Timing diag

ram

Output

The signal starts and stops timing.
The display is held and timing is continued if the reset
or gate input is received during timing operation.
The timer resets if the reset or gate input is received
when the timing operation is stopped.

Note: Output is instantaneous when setting is 0.

Power

Start signal

input

Gate/Reset

Display

(for elapsed

time)

*

flashes

*

Timing

RST

Basic Operation