DeviceNet Objects
Common Services
128
Get
Warning
Code and
Time Stamp
(Time Stamps
not available
in all
products)
STRUCT of
Warning
Code
WORD
Fault Code.
Warning Time
Stamp (Time
Stamps not
available in all
products)
STRUCT of
BYTE
1/100 Second (0 – 99).
BYTE
Second (0 – 59).
BYTE
Minute (0 – 59).
BYTE
Hour (0 – 23).
BYTE
Day of Week (0 – 6).
➀
BYTE
Date (1 – 31).
BYTE
Month (1 – 12).
BYTE
Year (0 – 99
➁
).
129
Get
Read
Warning Text
String Only
ARRAY of
BYTE
16 character string (no length
information, no terminating
null).
Service Code
Implemented for:
Service Name
Class
Instance
0x0E
Yes
Yes
Get_Attribute_Single
0x10
Yes
Yes
Set_Attribute_Single
Attribute
ID
Access
Rule
Name
Data Type
Description
➀
Sunday is a value of zero.
➁
Year is an offset from 1990.