Configuring the 1203-GU6 Enhanced DeviceNet Module Using a Serial Connection

8. Select the following settings:

9600 in the Bits per second field.
If you have previously set the module’s Serial Port Rate
parameter to enable 19200 bps, set the bps to 19200 in this
field.

8 in the Data bits field.

None in the Parity field.

1 in the Stop bits field.

None in the Flow control field.

9. Click OK. The HyperTerminal screen appears.

10. From the File menu, select Properties. The Properties dialog

box appears.

Figure 3.6

Properties Dialog Box

11. Click the Settings tab.

12. In the Function, arrow, and ctrl keys act as field, verify

Terminal keys is selected.

13. In the Emulation field, verify VT100 is selected.

14. Click OK.