Rockwell Automation 1762-IR4 RTD/Resistance Input Module User Manual

Page 79

Advertising
background image

Publication 1762-UM003A-EN-P - February 2003

Specifications A-3

Specification

1762-IR4

Accuracy Drift at 0 to 55° C (+32 to
+131°F)

±0.026°C/°C (0.026°F/°F) for Pt 385
±0.023°C/°C (0.023°F/°F) for Pt 3916
±0.012°C/°C (0.012°F/°F) for Ni
±0.015°C/°C (0.015°F/°F) for NiFe
±0.032°C/°C (0.032°F/°F) for Cu

±0.007

/°C (0.012

/°F) for 150

range

±0.023

/°C (0.041

/°F) for 500

range

±0.043

/°C (0.077

/°F) for 1000

range

±0.072

/°C (0.130

/°F) for 3000

range

Repeatability

(1)

±0.1°C (±0.18°F) for Ni and NiFe
±0.2°C (±0.36°F) to ±0.2°C (±0.36°F) for other RTD inputs
±0.04

for 150

resistances

±0.2

for other resistances

Excitation Current Source

0.5 mA and 1.0 mA selectable per channel

Open-Circuit Detection Time

(2)

6 to 1212 ms

Channel Update Time

Input filter and configuration dependent.

Input Channel Configuration

Via configuration software screen or the user program (by writing a unique bit pattern into the
module’s configuration file). Refer to your controller’s user manual to determine if user program
configuration is supported.

Calibration

The module performs autocalibration on channel enable and on a configuration change between
channels. You can also program the module to calibrate every five minutes.

Module OK LED

On: module has power, has passed internal diagnostics, and is communicating over the bus.
Off: Any of the above is not true.

Channel Diagnostics

Over- or under-range or broken input by bit reporting

Maximum Overload at Input Terminals

±35V dc continuous

Cable Impedance Max.

25

Ω (

Operating with >25

will reduce accuracy.)

Input Impedance

>10 M

Power Supply Distance Rating

6 (The module may not be more than 6 modules away from the system power supply.)

Channel to Bus Isolation

500V ac or 707V dc for 1 minute (type test)
30V ac/30V dc working voltage (IEC Class 2 reinforced insulation)

Channel to Channel Isolation

±10V dc

Vendor I.D. Code

1

Product Type Code

10

Product Code

65

(1) Repeatability is the ability of the module to register the same reading in successive measurements for the same input signal.
(2) Open-circuit detection time is equal to channel update time.