Installation

Chapter 3

3-5

Figure 3.3
Switch Settings for Network Link

O

O 1

2

N

F
F

Both switches ON for
57,600 bits per second

SW–5

13514

Asynchronous Communication Rate and Diagnostic Commands

Switch Assembly SW-6 lets you select the communication rate and
diagnostic commands for the KF2 module’s asynchronous port.

Communication Rate

Set the communication rate switches as shown:

Bits per

Set Switch:

Second as:

1

2

3

110

OFF

OFF

OFF

300

ON

OFF

OFF

600

OFF

ON

OFF

1,200

ON

ON

OFF

2,400

OFF

OFF

ON

4,800

ON

OFF

ON

9,600

OFF

ON

ON

Diagnostic Commands

Switch 4 determines how the KF2 module treats diagnostic commands
sent to it by a remote Data Highway station. You can connect the
asynchronous port of the KF2 module directly to a 1771-KG, 1773-KA,
or 1775-KA communication interface module (Figure 1.2). In such
applications, you can set Switch 4 so that the KF2 module either executes
any received diagnostic commands itself or passes those commands to the
other attached communication module.

If You Want Your Module to:

Set Switch 4:

Execute Received Diagnostic Commands

ON

Pass Any Received Diagnostic Commands to the
Attached Asynchronous Device

OFF

Advertising