Installing a Backup System

Chapter 2

2-11

Selecting a Backup Cable

Choose a backup cable for the switchover method desired. Table 2.C lists
the choices. See Figure 2.9 through Figure 2.11 for wiring information.

Table 2.C

Backup Cables

Switchover Method:

Backup Cable:

Automatic switchover with no switchback

1775ĆCBA

Automatic switchover with controllable switchback

1775ĆCBB

1

1775ĆCM

2

Manual switchover

1775ĆCBB

1. Use for scanner backup configuration.

2. Use for MX backup configuration.

Figure 2.9

Backup Cable Wiring for Scanner Backup with Automatic Switchover

with No Switchback (Cat. No. 1775ĆCBA)

1

3

2

4

5

6

1

3

2

4

5

6

1775ĆCBA

BACKUP CABLE

SCANNER #1

BACKUP

CONNECTOR

SCANNER #1

BACKUP

CONNECTOR

PRIMARY

PROCESSOR

BACKUP

PROCESSOR

SHIELD

10976ĆI