Table 4.K is a list of error codes. These error codes may appear while you
are controlling the operation of a memory communication module through
message instructions from a ladder program.

Table 4.K

Program Control Error Codes

Error Code

Description

1

Unknown command

2

Ambiguous command

Syntax errors that can

3

Invalid compare limits

be detected when the

4

Unknown object

instruction is enabled.

5

Invalid data table section

6

Missing object

7

Too many files in file list

8

Program control is not enabled

9

No communication between memory communication

modules in primary and backup processors

10

Commands not being sent by primary processor

Processing errors that

11

Insufficient memory available in backup processor

can occur while

12

Continuous transfer was not stopped

executing commands.

13

Memory communication module cannot lock the

backup system

14

Memory communication module cannot unlock the

backup system

15

File cannot be found or has zero length in primary

processor

16

Memory communication module cannot enable

outputs

Error Codes