1-4 Overview of the SLC Servo Module
SLC Servo Module
Specifications and
Compatibility
Selected specifications for the SLC Servo Module appear in the table
below.
1
There must not be other modules that generate module interrupts. Also, the STI and FAULT routines execute at a
higher priority than the module interrupt routine that is linked to the SLC Servo Module interrupt.
2
The SLC Servo Module does not function in a remote I/O rack.
The SLC Servo Module is compatible with:
•
SLC 5/03 FRN 5.0 (and above) processors.
•
RSLogix 500, AI500, or APS (version 5.0 or higher) software.
SLC Servo Module
Specification
Class
3
Number of Input
Words
12
Number of Output
Words
12
Selection for
Configuration
OTHER
(with 10114 as the number specified)
Configuration Mode
Uses M files
Recommended I/O
Slot in SLC Rack
Slot 1 or the lowest numbered I/O slot for SLC
applications using the module interrupt option.
1,2
Number of HSRVs in
one rack
12
with proper power supply