Connecting the termination panel – Rockwell Automation 1746-HSRV SLC Servo Control Module User Manual User Manual
Page 42

Publication 1746-6.1.2 - July 2000
Installing Your SLC Servo Module 4-7
Connecting the Termination
Panel
After mounting the termination panel, connect it to the SLC Servo
Module with the 1746-HCA cable. To connect the termination panel to
the SLC Servo Module:
1. Set the locking latches above and below the connector so the
latch reads OPEN.
2. Open the door of the SLC Servo Module.
3. Hold the connector as shown in Figure 4.5 (left) and insert it
into the D-sub connector on the SLC Servo Module until the
connector is seated.
4. Insert a small, flat-edge screwdriver next to the locking latch
located between the module door and connector.
5. Slide the locking latch to the right with your screwdriver.
6. Insert the small, flat-edge screwdriver next to the locking latch
located between the module door and connector.
7. Slide the locking latch to the left with your screwdriver.
8. Connect the other end of the cable to the 1746-HT termination
panel, as shown in Figure 4.5 (right).