Rockwell Automation 1746-HSRV SLC Servo Control Module User Manual User Manual
Page 88

Publication 1746-6.1.2 - July 2000
Setting Up Your SLC Servo Module 7-9
2. Select New. The Select Processor Type window appears.
3. Assign a name for your new RSLogix 500 project file and type it
in the Processor Name field.
4. Select your SLC processor from the list of processor types.
Default values assigned to the selected processor appear in the
Communications Setting area.
5. Select OK. The processor database is initialized and the RSLogix
500 navigator window appears with the name you typed in the
Processor Name field.
6. In the navigator window, double-click on I/O Configuration.
The I/O Configuration window appears. In the example below,
field 1 in the Racks area contains a four slot rack.
7. Your hardware configuration determines the number of slots in
the first rack.
If your SLC
rack has:
In field
1 of the Racks
area, select:
These slots appear
below the
Racks area in
the # column:
4 slots
1746-A4 4-Slot Rack
0-3