Span Your Valves

Chapter 9

9-13

We recommend that you span your pack and hold pressure valves for
optimum pressure performance in four parts:

Confirm critical values
Span your pack and hold pressure valves
Test valve linearity with a pressure vs. time profile
Set profile pressure alarms

Important: You may omit the subsection Span Your Pack and Hold
Pressure Valve
below if you have information from molding machine
OEMs or hydraulic valve manufacturers on spanning the working range of
valves. If available for your machine’s pack and hold pressure valve, enter
valve spanning values into pressure control limits PKC41-44 for Pack and
HDC41-44 for Hold, and proceed to Test Valve Linearity.

Important: If your machine hydraulics for pack and hold are identical to
those for injection, you may use your injection pressure valve spanning
parameters for pack and hold. If so, enter your values for INC41-44 into
PKC41-44 and into HDC41-44, and skip to Test Valve Linearity.

Important: If your machine controls cavity pressure during pack and hold,
follow the procedure for ram (screw) pressure and transfer the values to
PKC45-48 and HDC45-48 for cavity pressure. First confirm critical values.

Confirm Critical Values

Important: Confirm that all entries you made for configuration values
(chapter 7) and profile values (chapter 8) are as follows:

On

Worksheet

Confirm Your Configuration

With These Words or Bits

for Pack Pressure

ProĆSet Addr

7ĆB

(chapter 7)

QDC module output to which you connected your

pressure control valve

PKC02ĆB06, B05, B04

B38/148Ć150

SetĆoutput values for unselected valves

PKC09Ć12 = your values

N44:125Ć128

All ramping is disabled with zero ramp rates

PKC17Ć20 = 0

PKC25Ć28 = 0

N44:133Ć136

N44:141Ć144

Pressure limits:

Minimum Pressure Control Limit

Maximum Pressure Control Limit

Selected Pressure Valve, Output for Minimum

Selected Pressure Valve, Output for Maximum

PKC41 = 0

PKC42 = system pressure

PKC43 = your value

PKC44 = your value

N44:157

N44:158

N44:159

N44:160

Span Your Pack and Hold

Pressure Valves