Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.85(Passport) MNL. PLASTIC MOLDING MODULE User Manual

Page 182

Advertising
background image

Enter Your Values Here

Blank Worksheets

Appendix A

A-13

Worksheet 7ĆC (continued)
Hold Configuration Block (HDC)

Control Word ProĆSet 600 Addr. Value

Description

Units

HDC05

N44:181

1000

Minimum ERC PercentageĆĆCavity Pressure

Percent

8

HDC06

N44:182

1000

Minimum ERC PercentageĆĆRam (Screw) Pressure

Percent

8

HDC09

N44:185

*

Output #1 SetĆoutput Value During Profile

Percent Signal Output

4

HDC10

N44:186

*

Output #2 SetĆoutput Value During Profile

Percent Signal Output

4

HDC11

N44:187

*

Output #3 SetĆoutput Value During Profile

Percent Signal Output

4

HDC12

N44:188

*

Output #4 SetĆoutput Value During Profile

Percent Signal Output

4

HDC17

N44:193

0

Output #1 Accel Ramp Rate During Profile

Percent Signal Output per Second

5

HDC18

N44:194

0

Output #2 Accel Ramp Rate During Profile

Percent Signal Output per Second

5

HDC19

N44:195

0

Output #3 Accel Ramp Rate During Profile

Percent Signal Output per Second

5

HDC20

N44:196

0

Output #4 Accel Ramp Rate During Profile

Percent Signal Output per Second

5

HDC25

N44:201

0

Output #1 Decel Ramp Rate During Profile

Percent Signal Output per Second

5

HDC26

N44:202

0

Output #2 Decel Ramp Rate During Profile

Percent Signal Output per Second

5

HDC27

N44:203

0

Output #3 Decel Ramp Rate During Profile

Percent Signal Output per Second

5

HDC28

N44:204

0

Output #4 Decel Ramp Rate During Profile

Percent Signal Output per Second

5

HDC33

N44:209

*

Output #1 SetĆoutput Value at EndĆof Profile

Percent Signal Output

4

HDC34

N44:210

*

Output #2 SetĆoutput Value at EndĆof Profile

Percent Signal Output

4

HDC35

N44:211

*

Output #3 SetĆoutput Value at EndĆof Profile

Percent Signal Output

4

HDC36

N44:212

*

Output #4 SetĆoutput Value at EndĆof Profile

Percent Signal Output

4

HDC41

N44:217

0

Ram (screw) Pressure Minimum Control Limit

Pressure

3

HDC42

N44:218

*

Ram (screw) Pressure Maximum Control Limit

Pressure

3

HDC43

N44:219

*

Selected Ram (screw) Pressure Valve, Output for Minimum Percent Signal Output

4

HDC44

N44:220

*

Selected Ram (screw) Pressure Valve, Output for Maximum Percent Signal Output

4

HDC45

N44:221

0

Cavity Pressure Minimum Control Limit

Pressure

1

HDC46

N44:222

*

Cavity Pressure Maximum Control Limit

Pressure

1

HDC47

N44:223

*

Selected Cavity Pressure Valve, Output for Minimum

Percent Signal Output

4

HDC48

N44:224

*

Selected Cavity Pressure Valve, Output for Maximum

Percent Signal Output

4

HDC49

N44:225

100

Proportional Gain for Ram (screw) Pressure Control

None

HDC50

N44:226

400

Integral Gain for Ram (screw) Pressure Control

Inverse Time (algorithm)

6

HDC51

N44:227

0

Derivative Gain for Ram (screw) Pressure Control

Time (algorithm)

7

HDC52

N44:228

100

Proportional Gain for Cavity Pressure Control

None

HDC53

N44:229

400

Integral Gain for Cavity Pressure Control

Inverse Time (algorithm)

6

HDC54

N44:230

0

Derivative Gain for Cavity Pressure Control

Time (algorithm)

7

HDC57

N44:233

0

Profile High Ram (screw) Pressure Alarm Setpoint

Pressure

3

HDC58

N44:234

0

Profile High Cavity Pressure Alarm Setpoint

Pressure

1

1

Pressure

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00000 to 20000 PSI

00.00 to 99.99 inches per second

0000 to 9999 PSI

00.00 to 99.99

0000.0 to 2000.0 Bar

000.0 to 999.9 millimeters per second

000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999

00.00 to 99.99 minutes (ISA)

00.00 to 99.99 minutes (ISA)

00.00 to 99.99

00.00 to 99.99 seconds (AĆB)

00.00 to 99.99 seconds (AĆB)

* Refer to the appropriate section later in this chapter for information on this parameter

Advertising