3ć5, 3ć10, Configure the qdc module's i/o chapter 3 – Rockwell Automation 1771-QDC, D17716.5.85(Passport) MNL. PLASTIC MOLDING MODULE User Manual

Page 36

Advertising
background image

Enter Your Initial Values Here

Configure the QDC Module's I/O

Chapter 3

3-5

Category:

If your:

Then Use a Value Equal to:

Analog Signal @ Min Pressure

sensors are forwardĆacting

low end of your selected range

(Lines 7 and 15)

sensors are reverseĆacting

high end of your selected range

Analog Signal @ Max Pressure

sensors are forwardĆacting

high end of your selected range

(Lines 8 and 16)

sensors are reverseĆacting

low end of your selected range

Minimum Screw RPM (Line 9)

N/A

zero

Maximum Screw RPM

(Line 10)

N/A

max range value specified by

the manufacturer

Analog Signal @ Min RPM

sensors are forwardĆacting

low end of of your selected range

(Line 11)

sensors are reverseĆacting

high end of your selected range

Analog Signal @ Max RPM

sensors are forwardĆacting

high end of your selected range

(Line 12)

sensors are reverseĆacting

low end of your selected range

Worksheet 3ĆD

Determine Initial SensorĆconfiguration Values

Input

Line Control

Word

ProĆSet 600

Address

Value

Description

Units

1

1

MCC09

N40:5

0

Minimum Screw Position

Screw Axis Measured from zero

1

2

MCC10

N40:6

Maximum Screw Position

Screw Axis Measured from zero

1

3

MCC11

N40:7

Analog Signal @ Min Screw Position

Input Signal Range

2

4

MCC12

N40:8

Analog Signal @ Max Screw Position

Input Signal Range

2

2

5

MCC17

N40:13

0

Minimum Screw Pressure

Screw Pressure

3

6

MCC18

N40:14

Maximum Screw Pressure

Screw Pressure

3

7

MCC19

N40:15

Analog Signal @ Min Screw Pressure

Input Signal Range

2

8

MCC20

N40:16

Analog Signal @ Max Screw Pressure

Input Signal Range

2

3

9

MCC51

N40:47

0

Minimum Screw RPM

Rotational Speed

4

10 MCC52

N40:48

Maximum Screw RPM

Rotational Speed

4

11

MCC53

N40:49

Analog Signal @ Min Screw RPM

Input Signal Range

2

12 MCC54

N40.50

Analog Signal @ Max Screw RPM

Input Signal Range

2

4

13 MCC57

N40:53

0

Minimum Cavity Pressure

Cavity Pressure

5

14 MCC58

N40:54

Maximum Cavity Pressure

Cavity Pressure

5

15 MCC59

N40:55

Analog Signal @ Min Cavity Pressure

Input Signal Range

2

16 MCC60

N40:56

Analog Signal @ Max Cavity Pressure

Input Signal Range

2

1

Incremental Distance

2

Input Signal Range

3

Pressure

00.00 to 99.99in

00.00 to 10.00VDC or

0000 to 9999 PSI

000.0 to 999.9mm

01.00 to 05.00VDC or

000.0 to 999.9 Bar

04.00 to 20.00MADC

4

Rotational Speed

5

Pressure

000.0 to 999.9 RPM

00000 to 20,000 PSI

0000.0 to 2000.0 Bar

Advertising