Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.85(Passport) MNL. PLASTIC MOLDING MODULE User Manual

Page 186

Advertising
background image

PSC Block Identifier

Enter Your Values Here

Blank Worksheets

Appendix A

A-17

Worksheet 7ĆF
PostĆdecompression Configuration Block (PSC)

Control Word PSC01ĆBxx

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

ProĆSet 600 Addr. B38/bit

527 526 525 524 523 522 521 520 519 518 517 516 515 514 513 512

Value

0

0

0

0

0

0

0

0

0

0

0

1

0

0

0

0

Control Word ProĆSet 600 Addr.

Value

Description

Units

PSC05

N44:481

Incremental Movement Length

Incremental Distance

2

PSC08

N44:484

Movement Watchdog Timer Preset

Time

1

PSC09

N44:485

Output #1 SetĆoutput Value during Movement

Percent Signal Output

4

PSC10

N44:486

Output #2 SetĆoutput Value during Movement

Percent Signal Output

4

PSC11

N44:487

Output #3 SetĆoutput Value during Movement

Percent Signal Output

4

PSC12

N44:488

Output #4 SetĆoutput Value during Movement

Percent Signal Output

4

PSC17

N44:493

Output #1 Accel Ramp Rate during Movement

Percent Signal Output per Second

5

PSC18

N44:494

Output #2 Accel Ramp Rate during Movement

Percent Signal Output per Second

5

PSC19

N44:495

Output #3 Accel Ramp Rate during Movement

Percent Signal Output per Second

5

PSC20

N44:496

Output #4 Accel Ramp Rate during Movement

Percent Signal Output per Second

5

PSC25

N44:501

Output #1 Decel Ramp Rate during Movement

Percent Signal Output per Second

5

PSC26

N44:502

Output #2 Decel Ramp Rate during Movement

Percent Signal Output per Second

5

PSC27

N44:503

Output #3 Decel Ramp Rate during Movement

Percent Signal Output per Second

5

PSC28

N44:504

Output #4 Decel Ramp Rate during Movement

Percent Signal Output per Second

5

PSC33

N44:509

Output #1 SetĆoutput Value at EndĆof Movement

Percent Signal Output

4

PSC34

N44:510

Output #2 SetĆoutput Value at EndĆof Movement

Percent Signal Output

4

PSC35

N44:511

Output #3 SetĆoutput Value at EndĆof Movement

Percent Signal Output

4

PSC36

N44:512

Output #4 SetĆoutput Value at EndĆof Movement

Percent Signal Output

4

PSC57

N44:533

Movement High Pressure Alarm Setpoint

Pressure

3

1

Time

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00.00 to 99.99 seconds

00.00 to 99.99 inches per sec

0000. to 9999. PSI

00.00 to 99.99

000.0 to 999.9 millimeters per sec

000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999

00.00 to 99.99 minutes (ISA)

00. to 99.99

00.00 to 99.99

00.00 to 99.99 seconds (AĆB)

* Refer to the appropriate section later in this chapter for information on this parameter

Advertising