3ć14, Select optional configurations – Rockwell Automation 1771-QDC, D17716.5.85(Passport) MNL. PLASTIC MOLDING MODULE User Manual

Page 45

Advertising
background image

Configure the QDC Module's I/O

Chapter 3

3-14

8.

With your programming terminal, read the signal level returned in
SYS35 (N40:187) from your RPM sensor. You may wish to span
your RPM sensor at this time.

9.

Record this signal level on line 12 for MCC54.

10.

Release all flow and pressure from your screw motor and allow the
screw to return to rest.

You may now download your adjusted values to the QDC module using
the MCC download procedure presented earlier in this chapter.

You also have the option of configuring the following QDC features:

Use this Option:

For this Benefit:

Software Travel Limits

to guard against damaging the nozzle assembly or seals

Pressure Alarm Time Delay

to warn of excessive pressure without nuisance alarms

Digital Filter

to compensate for noise on position inputs

RPM Alarm Time Delay

to warn of excessive screw RPM without nuisance alarms

Configure Software Travel Limits

You may want to use the software restrictions to stop the travel of your ram
(screw) before it reaches its maximum limits (configured earlier in this
chapter).

Figure 4.1

Software Restrictions

Physical Travel Range

Min Position Max Position

d

d

Min SWTL Max SWTL

d = deadband

Safe Zone

During normal machine operation and whenever your cylinder travels
outside the safe zone (outside the specified software travel limits, SWTL),
the QDC module:

sets an alarm status bit
forces its outputs to zero

Select Optional

Configurations

Advertising