1771-6.5.85, a - worksheets, Blank worksheets – Rockwell Automation 1771-QDC, D17716.5.85(Passport) MNL. PLASTIC MOLDING MODULE User Manual

Page 170

Advertising
background image

System Operation:

Inject Mode 0 0

Select Units

0 = English

1 = metric

Code:

Your value

Required initial value

loaded by ProĆSet 600

0 or 1

Select Input 1 (Screw Position) Range

Select Input 2 (Screw Pressure) Range

Select Input 3 (Screw RPM) Range

Select Input 4 (Cavity Pressure) Range

Input Range

0 - 10 vdc

0

0

1 - 5 vdc

0

1

4 - 20 mA

1

0

Not connected

1

1

Code:

Your value

Required initial value

loaded by ProĆSet 600

0 or 1

Appendix

A

A-1

Blank Worksheets

Workshet 3ĆA

Select Module Parameters

Control Word MCC02ĆBxx

15

14 13 12

11

10

09 08 07 06 05 04 03 02 01 00

ProĆSet 600 Addr. B34/bit

543 542 541 540 539 538 537 536 535 534 533 532 531 530 529 528

Value

0

0

0

0

0

0

0

0

0

0

0

0

1

0

0

Example: If you select Inject operation with English units:

MCC02 = 00000000 00001000

Worksheet 3ĆB

Select Input Ranges for your Sensors

Control Word MCC03ĆBxx

15

14 13 12 11

10

09 08 07 06 05 04 03 02 01 00

ProĆSet 600 Addr. B34/bit

559 558 557 556 555 554 553 552 551 550 549 548 547 546 545 544

Value

1

1

1

1

1

1

1

1

Example: If you select an input range of 4-20mA for all four inputs,

MCC03 = 11111111 10101010.