Enter Your Values Here

Load Initial Configuration Values

Chapter 7

7-5

Worksheet 7ĆA (continued)
Injection Configuration Command Block (INC)

Control Word ProĆSet 600 Addr. Value

Description

Units

INC05

N44:1

1000

Minimum ERC PercentageĆĆVelocity

Percent

8

INC06

N44:2

1000

Minimum ERC PercentageĆĆPressure

Percent

8

INC09

N44:5

*

Output #1 SetĆoutput Value During Profile

Percent Signal Output

4

INC10

N44:6

*

Output #2 SetĆoutput Value During Profile

Percent Signal Output

4

INC11

N44:7

*

Output #3 SetĆoutput Value During Profile

Percent Signal Output

4

INC12

N44:8

*

Output #4 SetĆoutput Value During Profile

Percent Signal Output

4

INC17

N44:13

0

Output #1 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC18

N44:14

0

Output #2 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC19

N44:15

0

Output #3 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC20

N44:16

0

Output #4 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC25

N44:21

0

Output #1 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC26

N44:22

0

Output #2 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC27

N44:23

0

Output #3 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC28

N44:24

0

Output #4 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

INC41

N44:37

0

Pressure Minimum Control Limit

Pressure

3

INC42

N44:38

*

Pressure Maximum Control Limit

Pressure

3

INC43

N44:39

*

Selected Pressure Valve, Output for Minimum

Percent Signal Output

4

INC44

N44:40

*

Selected Pressure Valve, Output for Maximum

Percent Signal Output

4

INC45

N44:41

0

Velocity Minimum Control Limit

Velocity along Axis

2

INC46

N44:42

*

Velocity Maximum Control Limit

Velocity along Axis

2

INC47

N44:43

*

Selected Velocity Valve, Output for Minimum

Percent Signal Output

4

INC48

N44:44

*

Selected Velocity Valve, Output for Maximum

Percent Signal Output

4

INC49

N44:45

100

Proportional Gain for Pressure Control

None

INC50

N44:46

400

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

INC51

N44:47

0

Derivative Gain for Pressure Control

Time (Algorithm)

7

INC52

N44:48

200

Proportional Gain for Velocity Control

Inverse Time (Algorithm)

6

INC53

N44:49

0

Feed Forward Gain for Velocity Control

None

INC57

N44:53

0

Profile High Ram (screw) Pressure Alarm Setpoint Pressure

3

INC58

N44:54

0

Profile High Cavity Pressure Alarm Setpoint

Pressure

1

1

Pressure

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00000 to 20000 PSI

00.00 to 99.99 inches per second

0000 to 9999 PSI

00.00 to 99.99

0000.0 to 2000.0 Bar

000.0 to 999.9 millimeters per second

000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999

00.00 to 99.99 minutes (ISA)

00.00 to 99.99 minutes (ISA)

00.00 to 99.99

00.00 to 99.99 seconds (AĆB)

00.00 to 99.99 seconds (AĆB)

* Refer to the appropriate section later in this chapter for information on this parameter