Span Your Valves

Chapter 9

9-21

Before proceeding, observe these warnings:

ATTENTION: As with any machine start-up, make sure you
installed a test mold in the machine. Programming errors,
configuration errors, or hydraulic problems could lead to
machine damage or injury to personnel.

ATTENTION: Be sure all machine guards and shields are in
place before proceeding.

ATTENTION: Load the hopper with plastic before starting this
procedure. Absence of plastic during plastication:

* nullifies this procedure
* may cause excessive wear to the barrel and ram (screw)

Span Your Plastication Backpressure Valve

Span your plastication valve for smooth operation at the highest desired
backpressure. Do this by finding the optimum values for these words:

Minimum Pressure Control Limit PLC41 (N44:397)
Maximum Pressure Control Limit PLC42 (N44:398)
Selected Pressure Valve, Output for Minimum PLC43 (N44:399)
Selected Pressure Valve, Output for Maximum PLC44 (N44:400)

Important: If PanelView is operational, use it to:

observe actuals
change and download setpoints
run profiles

Important: We suggest that you read this entire procedure before starting.

1.

Jog your ram (screw) to the mold-end position.

2.

Set machine hydraulics to simulate ram (screw) backpressure:
enable pumps and align valves to normal state during plastication.

Important: Move injection carriage up to mold block to build pressure.