Rockwell Automation 1771-QDC, D17716.5.85(Passport) MNL. PLASTIC MOLDING MODULE User Manual

Page 171

Advertising
background image

Select Output 1 Range

Select Output 2 Range

Select Output 3 Range

Select Output 4 Range

Output Range

-10 to +10 vdc

0

0

0 to +10 vdc

0

1

4 to 20 mA

1

0

Not connected

1

1

Code:

Your value

Required initial value

loaded by ProĆSet 600

0 or 1

Blank Worksheets

Appendix A

A-2

Worksheet 3ĆC

Select Output Ranges for your Valves

Control Word MCC04ĆBxx

15

14 13 12 11

10

09 08 07 06 05 04 03 02 01 00

ProĆSet 600 B34/bit

575 574 573 572 571 570 569 568 567 566 565 564 563 562 561 560

Value

1

1

1

1

1

1

1

1

Example: If you select 0-10 vdc for all four output ranges,

MCC04 = 11111111 01010101.

Important: Software input/output selections must match the jumper
settings for each respective input/output.