Configure the QDC Module's I/O

Chapter 3

3-9

Actuate the Ram (screw) with SetĆoutput Operation

1.

Enter values that result in no motion in these DYC words

Output:

In Data Word:

At ProĆSet 600 Address:

1

DYC09

N40:121

2

DYC10

N40:122

3

DYC11

N40:123

4

DYC12

N40:124

2.

Enable set-output operation by entering a 1 in DYC01-B08 (Pro-Set
600 address B34/392). The QDC module sets outputs 1 - 4 to
percentage values that you entered in DYC09 - DYC12 respectively.

3.

With your programming terminal, slowly change the %-output value
of one output as you observe the corresponding movement.

Important: The DYC is constantly transferred to the QDC module, by
Pro-Set 600 software, so changes you make to %-output values are
immediately implemented.

Complete the procedure for configuring the QDC module to match its
sensors by spanning them over their intended range with the machine in
operation. Here we describe how you determine:

screw position sensor values
screw pressure sensor values
cavity pressure sensor values
screw RPM sensor values

In the procedures that follow, measure and record:

minimum and maximum positions
corresponding signal values
minimum and maximum pressures
corresponding signal values
minimum and maximum RPM
corresponding signal values

After determining these values from the procedures, write them down on
Worksheet 4-E.

Important: You must complete this configuration before proceeding to
any other chapters on module configuration.

Complete Your

Sensor Configuration