Rockwell Automation 1771-QDC, D17716.5.85(Passport) MNL. PLASTIC MOLDING MODULE User Manual

Page 34

Advertising
background image

Select Input 1 (Screw Position) Range

Select Input 2 (Screw Pressure) Range

Select Input 3 (Screw RPM) Range

Select Input 4 (Cavity Pressure) Range

Input Range

0 - 10 vdc

0

0

1 - 5 vdc

0

1

4 - 20 mA

1

0

Not connected

1

1

Code:

Your value

Required initial value

loaded by ProĆSet 600

0 or 1

Select Output 1 Range

Select Output 2 Range

Select Output 3 Range

Select Output 4 Range

Output Range

-10 to +10 vdc

0

0

0 to +10 vdc

0

1

4 to 20 mA

1

0

Not connected

1

1

Code:

Your value

Required initial value

loaded by ProĆSet 600

0 or 1

Configure the QDC Module's I/O

Chapter 3

3-3

Worksheet 3ĆB

Select Input Ranges for your Sensors

Control Word MCC03ĆBxx

15

14 13 12 11

10

09 08 07 06 05 04 03 02 01 00

ProĆSet 600 Addr. B34/bit

559 558 557 556 555 554 553 552 551 550 549 548 547 546 545 544

Value

1

1

1

1

1

1

1

1

Example: If you select an input range of 4-20mA for all four inputs,

MCC03 = 11111111 10101010.

Worksheet 3ĆC

Select Output Ranges for your Valves

Control Word MCC04ĆBxx

15

14 13 12 11

10

09 08 07 06 05 04 03 02 01 00

ProĆSet 600 B34/bit

575 574 573 572 571 570 569 568 567 566 565 564 563 562 561 560

Value

1

1

1

1

1

1

1

1

Example: If you select 0-10 vdc for all four output ranges,

MCC04 = 11111111 01010101.

Important: Software input/output selections must match the jumper
settings for each respective input/output.

Advertising