Install the QDC Module

Chapter 2

2-4

Table 2.A

Jumper Settings

Jumper

Function

Setting

E1

Run/Calibrate (Appendix G)

Calibrate = right

Run = left [1]

E5

I/O Density

Standard = top [1]

Do not use bottom position

E6

E7

E8

E9

Input 1 (Screw position)

Input 2 (Screw pressure)

Input 3 (Screw RPM)

Input 4 (Cavity pressure)

Voltage = right [1]

Current = left

E10

E14

E13

E17

Output 1 (Valve 1)

Output 2 (Valve 2)

Output 3 (Valve 3)

Output 4 (Valve 4)

Current = top

Voltage = bottom [1]

E11

E12

E15

E16

Output 1 (Valve 1)

Output 2 (Valve 2)

Output 3 (Valve 3)

Output 4 (Valve 4)

-10 to +10VDC = top

0 to +10VDC or

4 to 20mA = bottom [1]

[1] factoryĆset defaults

Important: If you select current output with jumper plugs E10, E14, E13,
and/or E17, then you must select the 4 to 20mA jumper position with E11,
E12, E15, and/or E16.

ATTENTION: If an output is unconnected, set the jumper
(E11, E12, E15, and/or E16) that corresponds to that output to 0
to 10 Vdc (bottom position). Setting the jumpers for –10 to +10
Vdc and later configuring the output as “unconnected” causes
the QDC module to output –10 Vdc on that channel when
stopped or when a system reset occurs and all outputs are forced
to 0% (i.e. 0% output equals –10Vdc).

Important: Selecting –10 to +10 VDC with jumper E11, E12, E15, and/or
E16 sets the QDC module for bi-directional valve operation. The
relationship to percentage output is as follows:

-10

0

10

0 10 20 30 40 50 60 70 80 90 100

%ĆOutput Requested

Output V

oltage (Vdc)