Use IOView to Verify the Configuration 6-13

Publication 1784-IN042A-EN-P - April 2005

2. Create either a Network view or an I/O Set view.

• To create a Network view, select EditCreate Network View.
• To create an I/O Set view, select EditCreate I/O Set View.

You see this screen:

3. Select OK to create the view.

In This Field

Do This

Port Number

Verify the Port Number corresponds to the 1784-PKTCS card for which you
want to create the view

Read/Write Period (ms)

Select the Read/Write Period (in milliseconds)

Privilege

Select whether the view is Read-Only or Read/Write

Watchdog

Set the card-to-driver watchdog timeout (in milliseconds)

TIP

Input data from a connection can be contained in multiple views. Output
data for a connection can be contained only in one view which has
Read/Write privileges.