A-6 Specifications

Publication 1784-IN042A-EN-P - April 2005

storage temperature

IEC 60068-2-1 (Test Ab, Un-packaged Non-operating Cold),

IEC 60068-2-2 (Test Bb, Un-packaged Non-operating Dry Heat),

IEC 60068-2-14 (Test Na, Un-packaged Non-operating Thermal
Shock):

-40 to 85

°C (-40 to 185 °F)

relative humidity

IEC 60068-2-30 (Test Db, Un-packaged Non-operating Damp Heat):

5 to 95% non-condensing

vibration

IEC 60068-2-6 (Test Fc, Operating):

2g @ 10-500Hz

operating shock

IEC 60068-2-27 (Test Ea, Unpackaged Shock):

30g

non-operating shock

IEC 60068-2-27 (Test Ea, Unpackaged Shock):

50g

emissions

CISPR 11:

Group 1, Class A

ESD immunity

IEC 61000-4-2:

6kV contact discharges

8kV air discharges

radiated RF immunity

IEC 61000-4-3:

10V/m with 1kHz sine-wave 80%AM from 80MHz to 2000MHz

10V/m with 200Hz 50% pulse 100%AM at 900MHz

10V/m with 200Hz 50% pulse 100%AM at 1890MHz

EFT/B immunity

IEC 61000-4-4:

+/-2kV at 5kHz on communications ports

surge transient immunity

IEC 61000-4-5:

+/-2kV line-earth (CM) on communications ports

conducted RF immunity

IEC 61000-4-6:

10Vrms with 1kH sine-wave 80% AM from 150kHz to 80MHz

enclosure type rating

none (open-style)

power requirements

In US, this equipment must be powered from UL Listed Information
Technology Equipment or UL Listed Industrial Control Equipment. In
Canada, this equipment must be powered by an SELV source, CSA
Certified Information Technology Equipment, or CSA Certified
Process Control Equipment.

5V dc, 700mA maximum, Class 2

power dissipation

3.5W

isolation voltage (continuous-voltage
withstand rating)

50V continuous

Tested to withstand 500V for 60 seconds.