Rockwell Automation 9323-PA2E APS SLC 500 Import/Export Utility User Manual User Manual
Page 103

Programming Instruction References
A-17
Instruction
Description
Parameter
Valid Addressing
Mode(s)
Valid File Types
Immediate
Values
SIN
➁
Sine
source
direct, indexed direct
indirect, indexed indirect
O, I, S, B, T, C, R,
N, F, A, ST, M
-32,768-32,767
fĆmin-fĆmax
destination
direct, indexed direct
indirect, indexed indirect
O, I, S, B, T, C, R,
N, F, A, ST, M
none
SQC
Sequencer Compare
file
indexed direct
indexed indirect
O, I, S, B, N, A, ST none
mask
direct, indexed direct
➄
indirect, indexed indirect
O, I, S, B, T, C, R,
N, A, ST, M
-32,768-32,767
source
direct, indexed direct
➄
indirect, indexed indirect
O, I, S, B, T, C, R,
N, A, ST, M
none
control
direct
R
none
length
1-255
position
0-255
SQL
➃
Sequencer Load
file
indexed direct
indexed indirect
O, I, S, B, N, A, ST none
source
direct, indexed direct
➄
indirect, indexed indirect
O, I, S, B, T, C, R,
N, A, ST, M
-32,768-32,767
control
direct
R
none
length
1-255
position
0-255
➁ Supported only by SLC 5/03 OS302 and SLC 5/04 OS401 processors.
➃ Supported only by SLC 5/02, SLC 5/03, and SLC 5/04 processors and MicroLogix 1000 controllers.
➄ Indexed addressing is not allowed when using T, C, R, or M addresses.