Creating an ASCII Documentation File

6-3

The example below shows an ASCII documentation file with a keyword for each
statement.

SYM

I:0.0/0

C5UNDERFL

AC

I:0.0/0

“Totalizer Pulse Counter”

IC

XIO

I:0.0/0

“North Cutter Running”

IC

JMP

2:LBL5

“Jump to label 5”

Keywords

ASCII Programming Instructions

ASCII Instruction Addresses

ASCII Address Comments

Placing Address Comments

An address comment is a text string (a maximum of 50 characters), which provides
notes or remarks for an address. To enter an address comment, keep the following
in mind:

Address comments should begin and end with quotation marks (“ ”), and should
follow the instruction address on the same line.

Do not use carriage returns. If you want a carriage return to appear in a
comment, use a back slash (\) in the comment to represent a carriage return.
(Note that this back slash is considered a character in the 50–character limit.)

Only the first 50 characters you enter are used in the comment. The
import/export utility displays 5 lines, 10 characters per line.

If you want a quotation mark to appear in a comment, use two adjacent
quotation marks. (One of the quotation marks is considered a character in the
50–character limit.)

If you enter a back slash in an address comment, precede the back slash with a
tilde (

).

Advertising