Selecting Import Options

After selecting [F5] – SELECT OPTIONS from the main import menu, the
import/export utility displays the Import Options window.

Rockwell Software Incorporated, Copyright 1989–19

9323 – PA2E

All Rights Reserved

File Names

TXT

TXT

TXT

TXT

Exists

SLC–500 APS IMPORT/EXPORT UTILITY

Press a Function Key

IMPORT

SOURCE

DESTIN:

IMPORT OPTIONS

ESC exits/ALT–U aborts changes

ASCII ARCHIVE FILE OPTIONS

F3 Ignore SLC Archive Errors

NO

ASCII PROGRAM DOCUMENTATION FILE OPTIONS

F5 On Collisions

DISCARD

F6 Default Keyword

SYMBOL

F7 Ignore TXT Documentation Errors

YES

F9 Save Configuration

ESC e

C:\IPDS\TEXT\SLC500

This screen offers you options for configuring the import of both ASCII archive and
documentation files. The function keys for this screen, with the exception of [F9] –
SAVE CONFIG, toggle through all the possible values for a given option.

For example, the “Ignore TXT Documentation Errors” option: Function key [F7] –
IGN TXT ERRORS toggles between the values “yes” and “no”, which are the only
possible values for this option.

Note

APSIE can import online edit INSERT, REPLACE, and DELETE rungs. You can
only create these rungs with an SLC 5/03 or SLC 5/04 processor. For more details
on the use of these rungs, see the Advanced Programming Software User Manual.