Creating an ASCII Archive File

5-3

Table 5.B
Defining Keywords for SLC 5/03 and SLC 5/04 Processors

This Keyword

Indicates

PROTECT_DATA

the type of DATA file protection applied to the specified file(s). The

following keywords are used in conjunction with PROTECT_DATA:

D CONSTANT Data file cannot be changed by the user or user

program during program operation.

D STATIC

Data file can only be changed by the user

program during program operation.

D MEM_MOD Protects individual data files from changes

during memory module transfers if the programs

match and are valid.

PROTECT_LAD

the LADDER file(s) specified are protected.

PROTECT_FORCE

that all FORCE file(s) are protected.

Operands

Operands are either logical addresses or immediate values. You can enter the
logical addresses in any valid format. The import utility generates the complete
address format. You may enter the immediate values in decimal, hex, octal, or
binary formats. See table 5.C.

Table 5.C
Defining Immediate Values

Format:

Description:

Example:

decimal

a number with an optional plus or minus sign and

decimal digits.

-32768

hex

a number that starts with a zero, followed by an X", then

any four characters from 0-9 or A-F.

OXFA90

octal

a number that starts with a zero, followed by an O",

then any six digits from 0 to 7.

0O370010

binary

a number that starts with a zero, followed by a B", then

up to 16 zeros or ones.

0B010110

floating point

a number with an optional plus or minus sign that falls in

the range of 3.402823x10

38

to 1.1754944x10

-38

or 0.0

-32768.00