Preface, Specifying the multi-point i/o list – Rockwell Automation 9323-PA2E APS SLC 500 Import/Export Utility User Manual User Manual
Page 69

Preface
APS Import/Export Utility User Manual
5-34
Specifying the Multi-Point I/O List
In the APS Import/Export Utility, the multi-point I/O list has been added to the
ASCII archive file for use with the SLC 5/03 OS302 and SLC 5/04 OS401
processors, and MicroLogix 1000 controllers.
The format for specifying the multi-point I/O list consists of a keyword
MULTIPOINT and a bit position, bit address, access flag, on description, and off
description. For example:
Bit
Address
MULTIPOINT
0
B3:1 1 “pilot light on” “pilot light off”
Keyword
Bit Position
Access
Flag
On Description
Off Description
There are 0–15 bit positions for MicroLogix 1000 controllers, and 0–31 bit positions
for SLC 5/03 OS302 and SLC 5/04 OS401 processors. An error occurs if you:
•
assign duplicate bit positions
•
specify more than 16 value pairs
•
use a bit address that is invalid for the selected controller
•
assign invalid state
If you do not use the keyword MULTIPOINT, or if you leave the value list empty,
APSIE initializes a default list of null values.