Specifying the program header – Rockwell Automation 9323-PA2E APS SLC 500 Import/Export Utility User Manual User Manual

Page 42

Advertising
background image

Creating an ASCII Archive File

5-7

Specifying the Program Header

The program header defines the target processor for the import utility. You must
provide information for this section of the archive file. (You could leave any of the
other six sections empty.)

The program header format for fixed and modular controllers consists of the
keyword “START” and the controller catalog number. Do not enter the catalog
number with tabs or spaces. For “other” fixed controllers the program header
format consists of the keyword “START”, “OTHER–1K” and the processor ID.
See table 5.E.

Table 5.E
Program Header Formats and Examples

Program Header Format:

Example Program Header:

START Controller_catalog_number

START 1747-L20A

START Other-1K Processor_ID

START OTHER-1K 1920

The available controllers include 20, 30, and 40 I/O fixed controllers, as well as 3
different modular processors. Input, output and line power information in the tables
is for reference only. See tables 5.F, G, H, I, and J.

If you use a fixed processor not specified in tables 5.F, G, or H, you must use the
processor name “OTHER–1K” (undefined fixed controller with 1K of memory).
The processor ID refers to the ID code specified in the user manual for your
processor.

Advertising