Rockwell Automation 2100 CENTERLINE Low Voltage Motor Control Centers  User Manual

Page 18

Advertising
background image

18

Rockwell Automation Publication 2100-IN012E-EN-P - February 2012

Chapter 1 General Information

NEMA Type 1 w/
gasket or Type
12
Series E...J

(7)

0.5

(2)

N or later

1.0 or
larger

A-E

(4)

(8)

F-L

(4)

M or later —

NEMA Type 1 w/
gasket or Type
12
Series K or later

0.5

(2)

N or later

1.0 or
larger

A-L

(4)

(8)

M or later

(1) When installing unit in topmost location in vertical sections, care must be taken to comply with the National Electric Code 6.7 ft (2000 mm) unit handle-to-floor height

limitation. A unit operating handle extender (catalog number 2100-NE1) that provides 3 in. (76.2 mm) added height flexibility is available.

(2) When CENTERLINE 2100, 0.5 space factor or Space Saving NEMA Starter plug-in units are ordered unassembled or ordered for existing sections, a centralized wiring

diagram holder kit (catalog number 2100H-WDH) should be ordered.

(3) Permits installation of 0.5 space factor or Space Saving NEMA Starter plug-in units in existing series E...J CENTERLINE 2100 vertical sections.

(4) Replacement and renewal parts are no longer supported. Contact Rockwell Automation LV MCC Technical Support at 1.440.646.5800 and follow the prompts to Allen-

Bradley>Low Voltage Motor Control Centers>Post Shipment Support.

(5) Required only if series F or later, 1.0 space factor or larger CENTERLINE 2100 unit is installed in topmost location of series A...E vertical sections.

(6) For more information regarding possible door hinge requirements, contact Rockwell Automation LV MCC Technical Support at 1.440.646.5800 and follow the prompts to

Allen-Bradley>Low Voltage Motor Control Centers>Post Shipment Support.

(7) Series E...J sections cannot accommodate 0.5 space factor or Space Saving NEMA Starter plug-in units in bottom-most unit location.

(8) A ground strap can be used to ground units rather than installing a ground bus. Refer to the CENTERLINE 2100 Motor Control Centers (MCC) Units with Vertical Operating

Handles Installation Instructions, publication

2100-IN014

.

Table 4 - MCC Modifications for Unit and Structure Compatibility

If Mounted in
this Type of
Section

(1)

,

(2)

Plug-in Units

No
Additional
Parts
Required

Requires
Style 1
Unit
Support
Pan

Requires
Style 3
Unit
Support
Pan

Requires
Style 3 Unit
Support
Pan w/
Bushing

Requires
Alternate
Top
Horizontal
Wireway
Pan

Requires
Door
Gasketing
Kit

Requires
Retrofit
Kit

(3)

Requires
Ground
Bus Kit

Space
Factor

Series

2100H-
UAJ1

2100H-
UA12100H
-UJ1

2100H-
USPA1
2100H-
USPJ1

2100H-
NA4A1
2100H-
NA4J1
2100H-
NA4A2
2100H-
NA4J2

2100-GJ10 2100H-

R1
2100H-
R2

2100H-
GS1

Advertising