4-2 Triggers and Filters

You can initiate only one specific Start Trigger: a Start Trigger on Data.
See page 4-4 for more information.

The following illustration shows start trigger conditions with a Start
Trigger on Data added.

Stop Trigger View

You see the Stop Trigger view when you click the Stop Trigger icon in
the Control Panel or from the Actions menu, click on Control
Panel>Define Stop Trigger
. There are two types of trigger conditions:
one related to the contents of the frames and the other related to the
time elapsed. You can combine the two types of conditions.
Triggering will stop provided at least one condition is met.

You can check the Center Trigger in Ring Buffer box to add data
following the first Stop on Conditions and keep the preceding data as
well. Otherwise, when the box is not checked, the data in the buffer is
the data preceding the Stop Trigger.

The Stop Trigger view is shown below.

Start Trigger on Data.

Stop without conditions.

Stop with conditions.

Define how much time is
needed to stop the
analysis after a Start.

Stop the trigger in the center
of the Ring buffer, keeping
data preceding and adding
data following the given
condition.

Enable/disable
trigger condition.

Stop trigger condition.