4-12 Triggers and Filters
You can add, edit, or delete a post-filter condition in these two list
areas by clicking the right mouse button. A pop-up menu appears.
When you add or edit a post-filter in the top list, you see the
following dialog box:
TIP
Another way you can add, edit, or delete a post-filter condition
is by pressing the Insert, Enter, or Delete key, respectively.
Define the Producer MAC ID(s) you want to filter. You can define:
•
a single Producer MAC ID (in a range 0-255).
•
a group of IDs. Separate the range by a hyphen (2-88).
The range can extended from 0 to 255.
•
multiple IDs. Separate the IDs by a semi-colon (2;9;27).
•
a group and multiple IDs (2-7;3;8).
If you do not enter a value in this field, the full range (0-255) becomes the default value.
Enable filter on an LPacket. This enables the
bottom post-filter list. You will see a “Yes” in the
Filter LPacket column in the Filter/Trigger view.
Disable filter on an LPacket. This disables the
bottom post-filter list. You will see a “No” in the
Filter LPacket column in the Filter/Trigger view.
TIP
For a definition of Status, see page 4-4.
For a definition of Type, see page 1-2.