Good scheduled data example – Rockwell Automation 9220-WINTA ControlNet Traffic Analyzer Reference Manual User Manual
Page 79
Publication 9220-052C-EN-P - August 2002
Troubleshooting 8-3
Refer to the following two examples for clarification.
Good Scheduled Data Example
Following the procedure below to define only good scheduled data.
1. Define the start condition as Start Always.
2. Define the stop condition as No Stop Condition.
3. Define the pre-filter condition as Filter on Conditions.
4. Click the right mouse button in Filter/Trigger view and select
Add Filter Condition.
5. Check only the Good status and Scheduled type boxes in the
Edit Filter dialog box.
6. Click OK.
Pre-Filter Filter/Trigger view should look like the following illustration.
Only good scheduled data will pass through the hardware and
be seen by the software.
All Unscheduled Data Starting on Good Moderator Example
Following the procedure below to define all unscheduled data starting
on good moderator.