Time display, Data format, Time display -2 data format -2 – Rockwell Automation 9220-WINTA ControlNet Traffic Analyzer Reference Manual User Manual

Page 52: 2, fo

Advertising
background image

Publication 9220-052C-EN-P - August 2002

5-2 Display Information

Time Display

The time can be expressed as absolute or relative. You can also
change the time resolution.

The Display View Options dialog box appears when you click on the
Display icon on the Control Panel or, in the MAC Frame Data view
area, click right with the mouse button and click Define Display.

The time display options are defined below.

You can change the type of time information that will show in MAC
Frame Data view.

Data Format

The following section describes the three data format options.

Data can be viewed in three ways:

MAC Frame

LPacket

Interpreted

Click this button

To

No Time

remove the Time column from MAC Frame Data view.
Select this option if the time is not significant.

Absolute Time

express the time as absolute – from the time when ASIC
was started.

Relative Time

express the time as relative to the first pre-filter frame.

Time between Frames

express the time between two sequential frames in MAC
Frame Data view.

IMPORTANT

If the last record was configured with the Pre-Filter Disable
Time Stamp
option enabled, all Time Display options will be in
shadow (no access to them). The No Time option will be forced.

Click on

To show the time the data was collected in

Days

days, hours, minutes, and seconds

Hours

hours, minutes, and seconds

Minutes

minutes and seconds

Seconds

seconds

Advertising