Rockwell Automation 9220-WINTA ControlNet Traffic Analyzer Reference Manual User Manual

Page 49

Advertising
background image

Publication 9220-052C-EN-P - August 2002

Triggers and Filters 4-15

When you choose the Generic Tag option, the Connection field appears
and you see the following dialog box:

If you don’t enter a value in the Ctrl Bits field, “Generic” appears
in the Control Bits column in the bottom list area of Post-Filter
view. If the Ctrl Bits field is filled in, the interface checks the
consistency with the Generic Tag option; in the Post-Filter view,
Control Bits field, a hexadecimal value will replace the “Generic”
string. See “Interpreting Control Bits,” on the next page.

IMPORTANT

When Generic Tag is chosen, it is not necessary to fill any
fields because the

Generic Tag option is automatically entered

on several bits in the Control Bits field.

When Generic Tag is chosen, the Connection
Number field appears.

Enter the Connection
Number in hexadecimal.