Triggers and Filters 4-5
Each byte in the LPacket Header can be checked; a sequence of a
maximum of 8 bytes will appear in the LPacket data field.
When you choose to start a trigger on a condition, a trigger list area
appears. You can add, edit, or delete a Start Trigger on Data condition
in this list area by clicking the right mouse button. A pop-up menu
appears. Only one Start Trigger on Data can be created at one time.
Once a Start Trigger on Data has been added, it can be edited or
deleted. Also, you can create a Start Trigger on Data only on Good
Scheduled or Good Unscheduled frames.
If you choose to add or edit a Start Trigger on Data, the Trigger on
data
dialog box appears. You must enter a value in the Producer MAC
ID and/or Consumer MAC ID, and link data (if an offset is defined)
field(s). Three examples follow showing the different options you can
choose in this dialog box.