Current loop, Velocity loop, Position loop – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 140: Digital inputs

Publication 2092-UM001D-EN-P — July 2005
A-6
Specifications and Dimensions
Current Loop
Velocity Loop
Position Loop
Digital Inputs
Update Period
50
µS
-3dB Bandwidth
2 kHz, typical
-45
o
Bandwidth
350 Hz, typical
Type
PI, Flux Vector Control, Space Vector Modulation
Features
Notch Filter, Low Pass Filter, Automatically tuned using motor
parameters
Update Period
200
µS
-3dB Bandwidth
550 Hz achievable through tuning
Type
PID
Features
Low Pass Filter, Online Inertia Identification, Velocity Observer
Update Period
200
µS
Type
P with Kff
Features
Low Pass Filter
Quantity
7 general purpose, opto-isolated
Type
Active low, single-ended (switch closure to common activates)
Input Current
6 mA, typical
Input Voltage
21.6–26.4 Volts
Propagation Delay
50
µs
Firmware Scan Delay
6 ms
Assignable Functions
Alternate Gain Select, Current Limit – Negative, Current Limit –
Positive, Drive Enable, Fault Reset, Integrator Inhibit, Operation
Mode Override, Overtravel – Negative,
Overtravel – Positive, Pause Follower, Position Strobe, Preset
Direction, Preset Select 1 to 3, Reset Multi-turn Data, Zero Speed
Clamp Enable