D-16
Ultra1500 Operator Interface
Pr-1.02 Main Velocity Regulator Gains: Integrator Time
Pr-1.03 Main Position Regulator Gains: Kp
Pr-1.04 Main Current Regulator Gains: Lowpass Filter Bandwidth
Pr-1.05 Main Velocity Regulator Gains: Low Pass Filter Bandwidth
Pr-1.06 Reserved
Pr-1.07 Main Current Regulator Gains: Resonant Frequency
Suppression
Range:
0 to 60000
Default:
26
Applicable Operating Mode:
Follower, Analog Velocity, Preset Velocity
Ultraware Link:
Main Velocity Regulator Gains: Integrator Time
Range:
0 to 700
Default:
20
Units:
Hz
Applicable Operating Mode:
Follower
Ultraware Link:
Main Position Regulator Gains: Kp
Range:
0 to 10000
Default:
300
Units:
Hz
Applicable Operating Mode:
All
Ultraware Link:
Main Current Regulator Gains: Lowpass Filter Bandwidth
Range:
0 to 10000
Default:
1000
Units:
Hz
Applicable Operating Mode:
Follower, Analog Velocity, Preset Velocity
Ultraware Link:
Main Velocity Regulator Gains: Low Pass Filter Bandwidth
This parameter is Reserved.
Description:
Suppresses vibration by cutting off the Current Command in
the assigned frequency band.
Range:
0 to 10000
Default:
10000