Position command inputs, Position command inputs -12 – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 42

Publication 2092-UM001D-EN-P — July 2005
2-12
Ultra1500 Connector Data
Position Command Inputs
The Ultra1500, when operating in follower mode, accepts position command
signals from a controller.
Position command inputs can be A quad B, Step/Direction, or Step Up/
Step Down format as shown in Figure 2.8.
Figure 2.8
Position Command Input Signal Types
Figure 2.9 shows the configuration of the Position Command inputs, and the
following table provides descriptions of these inputs.
Figure 2.9
Position Command Interface Example
Parameter
Description Minimum
Maximum
ON State Input
Voltage
Input voltage difference between the + input
and the - input that is detected as an ON
state.
2.8V
3.7V
STEP (CN1-11 and -12)
DIRECTION (CN1-13 and -14)
STEP UP (CN1-11 and -12)
STEP DOWN (CN1-13 and -14)
A (CN1-11 and -12)
B (CN1-13 and -14)
+5V
AX-
680
Ω
Logic Ground
M456
1 k
Ω
0.001
µF
150
Ω
AX+
Ultra1500
Drive