Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 178

Publication 2092-UM001D-EN-P — July 2005
D-14
Ultra1500 Operator Interface
Pr-0.09 Input Signal Assignment - Group 5
Pr-0.10 Output Signal Assignment – Group 1
Pr-0.11 Output Signal Assignment – Group 2
Data Size:
4 digits
Digits: Digit
Description
Default
0 Position
Strobe 0x0
1 Reserved
0x0
2 Reserved
0x0
3 Reserved
0x0
Applicable Operating Mode
All
Range for all digits:
0 to 3
Value Description
0
Output Signal OFF
1 to 3
Output signal assigned to
hardware outputs 1 through 3
Data Size:
4 digits
Digits: Digit
Description
Default
0 In
Position
0x0
1 Up
To
Speed
0x0
2 Brake
control
0x0
3
Within Speed Window
0x0
Applicable Operating Mode
All
Range for all
digits:
0 to 3
Value Description
0
Output Signal OFF
1 to 3
Output signal assigned to
hardware outputs 1 through 3
Data Size:
4 digits
Digits: Digit Description
Default
0 Current
Limited 0x0
1 Velocity
Limited
0x0
2 Near
Position
0x0
3 Warning
0x0
Applicable
Operating
Mode
All