Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 192

Publication 2092-UM001D-EN-P — July 2005
D-28
Ultra1500 Operator Interface
Pr-5.11 Reserved
Pr-5.12 Analog Output 1: Signal
Pr-5.13 Analog Output 2: Signal
Pr-5.14 Analog Output 1: Scale
Pr-5.15 Analog Output 2: Scale
Units:
msec
Applicable Operating Mode:
All
Ultraware Link:
AC Line Loss Fault Delay
This parameter is Reserved.
Description:
The drive signal assigned to channel 1 from the Channel
Setup dialog box in the Oscilloscope window.
Range:
1 to 99999
Default:
0x00
Applicable Operating Mode:
See Monitor Variable Numbers (except 0x0F) beginning on
page D-6.
Ultraware Link:
Analog Output 1: Signal
Description:
The drive signal assigned to channel 2 from the Channel
Setup dialog box in the Oscilloscope window.
Range:
1 to 99999
Default:
See Monitor Variable Numbers (except 0x0F) beginning on
page D-6.
Applicable Operating Mode:
All
Ultraware Link:
Analog Output 2: Signal
Description:
The amplitude of the channel 1 input signal to be displayed by
the oscilloscope.
Range:
1 to 99999
Default:
500
Units:
See Monitor Variable Numbers (except 0x0F) beginning on
page D-6.
Applicable Operating Mode:
All
Ultraware Link:
Analog Output 1: Scale
Description:
The amplitude of the channel 2 input signal to be displayed by
the oscilloscope.
Range:
1 to 99999
Default:
500