Status mode – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 171

Publication 2092-UM001D-EN-P — July 2005
Ultra1500 Operator Interface
D-7
Status Mode
The Status mode provides normal operational information, fault indicators,
and positive or negative overtravel indicators. The operational information
displayed may be grouped into three categories:
• Control Mode (characters 0 and 1),
• Row Display (character 2), and
• Status (characters 3 through 5).
15
Input and Output Status
16
Error History
Up to eight alarms stored in numerical order (most
recent =1, to oldest =8) with error code number:
Most significant digit is alarm number (1–8),
Least significant six digits are the error code number
referenced in the Error Displays beginning on page 6-5.
e.g., 1-E004 = most recent error is a Motor Overtemp
17
V Phase Current
0.001 A
18
W Phase Current
0.001 A
19
Motor Temperature
%
20
Analog Command -
Velocity
0.01 V
21
Analog Command -
Current
0.01 V
22
Current Feedback
0.01 V
23
Hall State
–
24
Motor Feedback Position counts
25
Instantaneous Output
Power
Watts
26
Output Power Limit
Ratio
%
27
Instantaneous Shunt
Power
Watts
28
Drive Utilization
%
29
Reserved
–
Variable
Numbers
Name
Unit
Digital Outputs 3 - 1:
3 and 1 active
Servo Alarm:
No errors
E-Stop:
Not active
Digital Inputs 7 - 1:
6, 5, 3, and 1 active
7
1
3
1
2
3
2
5
4
6