Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 185

Publication 2092-UM001D-EN-P — July 2005
Ultra1500 Operator Interface
D-21
Pr-2.10 Preset Velocity 6
Pr-2.11 Preset Velocity 7
Pr-2.12 Manual Velocity Limit
Pr-2.13 Velocity Limits: Velocity Limit Mode
mm/sec for linear motors
Applicable Operating Mode
Preset Velocity
Ultraware Link:
Preset Velocity 5
Range:
-5000 to5000
Default:
0
Units:
rpm for rotary motors
mm/sec for linear motors
Applicable Operating Mode
Preset Velocity
Ultraware Link:
Preset Velocity 6
Range:
-5000 to5000
Default:
0
Units:
rpm for rotary motors
mm/sec for linear motors
Applicable Operating Mode
Preset Velocity
Ultraware Link:
Preset Velocity 7
Range:
1 to 10000
Default:
10000
Units:
rpm for rotary motors
mm/sec for linear motors
Applicable Operating Mode
Follower, Analog Velocity, Preset Velocity
Ultraware Link:
Manual Velocity Limit
Range: Value
Description
0x0
Disabled
0x1
Limited by (Pr-2.12).
0x2
Limited by Analog Speed Command Value
(except Analog Speed Mode).
0x3
Limited by lesser one between (Pr-2.12)
and Analog Speed Command.
Default:
0
Applicable Operating Mode
All
Ultraware Link:
Velocity Limits: Velocity Limit Mode