Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 194

Publication 2092-UM001D-EN-P — July 2005
D-30
Ultra1500 Operator Interface
Pr-6.05 Reserved
Pr-6.06 Fault Detail Setup: Sample Period
Pr-6.07 Fault Detail Setup: Channel A
Pr-6.08 Fault Detail Setup: Channel B
Pr-6.09 Fault Detail Setup: Channel C
Default:
0
Applicable Operating Mode:
Follower, Analog Velocity, Preset Velocity
Ultraware Link:
Main Velocity Regulator Gains: D
This parameter is Reserved.
Description:
The time, in 0.2 msec increments, between signal samples.
50 samples constitute a fault trace.
Range:
1 to 99
Default:
5
Units:
0.2 msec
Ultraware Link:
Fault Detail Setup: Sample Period
Description:
Selects the drive signal to assign to a Channel A.
Range:
See Monitor Variable Numbers (except 0x0F) beginning on
page D-6.
Default:
0x00
Ultraware Link:
Fault Detail Setup: Channel A
Description:
Selects the drive signal to assign to Channel B.
Range:
See Monitor Variable Numbers (except 0x0F) beginning on
page D-6.
Default:
0x03
Ultraware Link:
Fault Detail Setup: Channel B
Description:
Selects the drive signal to assign to Channel C.
Range:
See Monitor Variable Numbers (except 0x0F) beginning on
page D-6.
Default:
0x0B
Ultraware Link:
Fault Detail Setup: Channel C