Group 2 Parameters provide speed control settings.
Pr-2.00 Analog Velocity Command Scale
Pr-2.01 Jog Velocity Command
Pr-2.02 Acceleration Limits: Acceleration
Pr-2.03 Acceleration Limits: Deceleration
Pr-2.04 Acceleration Limits: S-Curve Time
Range:
100 to 20000
Default:
5000
Units:
rpm/V*10 for rotary motors
mm/sec/V*10 for linear motors
Applicable Operating Mode:
Analog Velocity
Range:
0 to 5000
Default:
500
Units:
rpm for rotary motors
mm/sec for linear motors
Applicable Operating Mode:
All
Range:
0 to 60000
Default:
0
Units:
msec
Applicable Operating Mode:
Analog Velocity, Preset Velocity, Follower
Ultraware Link:
Acceleration Limits: Acceleration
Range:
0 to 60000
Default:
0
Units:
msec
Applicable Operating Mode:
Analog Velocity, Preset Velocity, Follower
Ultraware Link:
Acceleration Limits: Deceleration
Range:
0 to 5000
Default:
0
Units:
msec
Applicable Operating Mode:
Analog Velocity, Preset Velocity, Follower
Ultraware Link:
Acceleration Limits: S-Curve Time