P232

Filter Time For Overspeed Fault (Lower Limit)

100

ON

0

32767

P233

Threshold Of Over-Speed Fault At Lower Frequency Limit 20

ON

0

199.99

P234

Threshold Of Over-Speed Fault At Upper Frequency Limit 20

ON

0

199.99

P235

Frequency Deviation Warning Cancellation Threshold

0.99

ON

0

199.99

P236

Frequency Deviation Warning Threshold

6

ON

0

199.99

P237

Frequency Deviation Warning Delay (ms)

8

ON

0

32767

P238

Motor Stall Fault Threshold

10

ON

0

199.99

P239

Motor Stall Fault Delay (ms)

6000

ON

0

32767

P240

Transformer Over Temperature Fault Delay (ms)

5000

ON

0

32767

P241

Transformer Over Temperature Warning Delay (ms)

5000

ON

0

32767

P247

Software Interlock: 1-Disable, 0-Enable

1

ON

0

1

P250

Input Contactor/Circuit Breaker Close Delay (ms)

5000

ON

0

10000

P251

Frequency Command-Low Frequency Region Boundary

0.5

ON

0

100

P252

Motor In Stopping Condition Threshold

1

ON

0

100

P253

Motor Coast Stop Time

10

ON

0

10000

P256

Ground Fault Warning Cancellation Threshold

10

ON

0

199.99

P257

Motor Stall Warning Cancellation Threshold

2.98

ON

0

199.99

P259

Frequency Command Analog Offset

0

ON

-100

199.99

P260

Frequency Command Analog Scaling Factor

100

ON

0

199.99

P261

Frequency Command Analog Minimum

0.49

ON

0

199.99

P262

Frequency Command Source Selection: 0-Digital, 1-
Analog

0

OFF

0

1

P270

Delayed Lockout Time Of Stop Operation (ms)

2000

ON

0

5000

P271

Flux Delay (ms)

50

ON

0

5000

P300

Digital Output #0 Memory Address

99

ON

0

500

P301

Digital Output #0 Logic: 1-Inverting, 0-Non-Inverting

0

ON

0

1

P302

Digital Output #0 Bit Selection (0...15)

0

ON

0

15

P303

Digital Output #0 Delay (ms)

0

ON

0

32767

P304

Digital Output #1 Memory Address

99

ON

0

500

P305

Digital Output #1 Logic: 1-Inverting, 0-Non-Inverting

0

ON

0

1

P306

Digital Output #1 Bit Selection (0...15)

1

ON

0

15

P307

Digital Output #1 Delay (ms)

0

ON

0

32767

P308

Digital Output #2 Memory Address

99

ON

0

500

P309

Digital Output #2 Logic
1: Inverting
0: Non-Inverting

0

ON

0

1

P310

Digital Output #2 Bit Selection (0...15)

2

ON

0

15

P311

Digital Output #2 Delay (ms)

0

ON

0

32767

P312

Digital Output #3 Memory Address

99

ON

0

500

Parameter
Number

Description

Default
Value

Modify
Root

Lower
Limit

Upper
Limit