Install a Tap Through the Body Holes

Mount the tap to a suitable fixture by threading the screws through the body
holes, as shown in the illustration on the right.

When using screws and flat washers, any suitable hardware can be used,
provided the diameter is less than 4 mm (0.15 in.).

The illustration on the left shows a tie wrap threaded through the body holes.

Install a Repeater

To install a repeater adapter, see the ControlNet Modular Repeater Adapter
Installation Instructions, publication

1786-IN013

.

Install Cable Connectors

See the following instructions to attach cable connectors to the ends of your
trunk-cable sections:

Obtain the Toolkit

Calibrate the Cutting Blades

Strip the Cable

Attach the Connectors to the Cable

Test for Electrical Shorts and Continuity

20083

ATTENTION

Do not over-tighten the screws. Over-tightening the screws can
damage the tap. The applied torque should be
0.2…0.4 N

m (1…2 lb

ft).