Installing the Serial Converter

Use the following procedure and refer to figure 3.2 to install the
serial converter.

Step 1. Connect the serial converter to the product using the

RECBL-M10 cable.

Step 2. Connect the converter to the computer using the

RECBL-SFC cable.

Step 3. Verify that power is applied to the product. The serial

converter receives power from the product. Therefore, the
product must be powered before the serial converter will
operate.

The diamond light on the serial converter flashes green to indicate
that the serial converter is properly installed and receiving power. If
it is not green, refer to Chapter 5, Troubleshooting.

3.3

Removing the Serial Converter

Use The followoing procedure to disconnect the serial converter

Step 1. Disconnect the RECBL-M10 cable from the product and

then from the serial converter. To disconnect it, gently push
it in and then pull it out.

Step 2. Disconnect the RECBL-SFC serial cable from the serial

converter and then the computer.

Figure 3.2 – Connecting the Cables to the Serial Converter

RX

TX

Step 1

Step 2

!

ATTENTION: If the serial converter is transmitting control I/O
to the product (indicated by a solid green diamond LED), the
product may fault when you remove or reset the serial
converter. Determine how your product will respond before
removing or resetting a connected serial converter. Failure to
observe these precautions could result bodily injury and/or
damage to equipment.