2 module diagnostic items, 3 viewing and clearing the event queue – Rockwell Automation RECOMM-232 Serial Converter for use with DPI AC Drives User Manual

Page 30

Advertising
background image

5-4

Serial Converter for use with DPI AC Drives

5.2

Module Diagnostic Items

The following diagnostic items can be accessed using VS Utilities.

5.3

Viewing and Clearing the Event Queue

It is normal for the event queue in the serial converter to contain
events. If you encounter unexpected communication problems, you
can access the event queue and view the most recent events. To
view the event queue:

Step 1. Access the event queue using a configuration tool. Refer to

section 4.1.

Step 2. Scroll through events in the event queue. The most recent

event can be found at 2R > Event Queue 1. See figure 5.2.

Table 5.4 – Diagnostic Items Accessed Using VS Utilities

Name

Description

Common Logic
Cmd

Current value of the Common Logic Command being
transmitted to the host by this peripheral.

Prod Logic
Cmd

Current value of the Product Specific Logic Command
being transmitted to the host by this peripheral.

Reference

Current value of the Product Specific Reference being
transmitted to the host by this peripheral.

Common Logic
Sts

Current value of the Common Logic Status being received
from the host by this peripheral.

Prod Logic Sts

Current value of the Product Specific Logic Status being
received from the host by this peripheral.

Feedback

Current value of the Product Specific Feedback being
received from the host by this peripheral.

DPI Rx Err

Current value of the DPI CAN Receive Error Counter
register.

DPI Rx Err Max Maximum value of the DPI CAN Receive Error Counter

register.

DPI Tx Err

Current value of the DPI CAN Transmit Error Counter
register.

DPI Tx Err Max Maximum value of the DPI CAN Transmit Error Counter

register.

Field Flash Cntr Current value of the Field Flash Counter.

CPU

CPU Type.

Figure 5.2 – Viewing the Event Queue

Press the UP ARROW or DOWN ARROW key to scroll

through the parameter list. Press the LEFT ARROW or

RIGHT ARROW key to modify parameter values. Press

the ENTER key to save a new value.

2R> Event Queue 1 = Pin ID Change